Country Korea;
Production Korea;
Boiler type Volatile;
Working hours Heating / hot water supply;
The combustion chamber Closed;
Burner Modulated;
Max power, kW 13;
Min power, kW 7;
Max pressure will heat the circuit, atm 3;
Min pressure will heat the circuit, atm 0.6;
Expansion tank Yes;
Circulation pump Yes;
Built-in storage boiler No;
Possibility of connecting a hot water boiler None;
Heat exchanger type Separated;
Max pressure in the DHW circuit, atm 8;
Min pressure in the DHW circuit, atm 0.3;
Performance 916; DHW 30C, l / min 13.8;
Min consumption of natural gas, msup3; / h 0.75;
Max natural gas consumption, msup3; / h 1.4;
Min consumption of liquefied gas, kg / h 0.63;
Max consumption of liquefied gas, kg / h 1.16;
Nominal pressure of natural gas, mbar 25;
Chimney connecting diameter, mm No;
Gas pipeline connecting diameter, inch 1/2;
Separate chimney diameter, mm No;
Connecting diameter heating circuit, inch 3/4;
Connecting diameter DHW circuit, inch 1/2;
Electric power, W 150;
Current frequency, Hz 50;
Mains voltage, V 220 V;
Dimensions HxWxD, cm 69.5x44x26.5;
Weight, kg 28;
Warranty 2 years;
type of instalation Vertical;
Weather-dependent automation No;
Self-diagnosis No;
Underfloor heating mode No;
Remote control No;
Frost protection Yes;
Overheat protection thermostat No;
Low NOx level No;
Electronic control system Yes;
Mechanical control system No;
Pressure gauge Yes;
Condensate protection of the heat exchanger No;
Ionization flame control No;
Anti-blocking pump Yes;
Bypass loop No;
Functional LCD No;
Emergency coolant discharge No;
Electronic cascade control unit No;
Gas valve Multiblock No;
Can be installed in a residential area None;
Operation in a separate boiler room No;
Russified interface Yes;
Intuitive controls Yes;
Height-adjustable boiler legs No;
Water flow sensor No;
Height, cm 70;
Width, cm 44;
Depth cm 27;
Width 440;
Height 695;
Depth 265;
Country Korea;
Production Korea;
Boiler type Volatile;
Working hours Heating / hot water supply;
The combustion chamber Closed;
Burner Modulated;
Max power, kW 16;
Min power, kW 9;
Max pressure will heat the circuit, atm 3;
Min pressure will heat the circuit, atm 0.6;
Expansion tank Yes;
Circulation pump Yes;
Built-in storage boiler No;
Possibility of connecting a hot water boiler None;
Heat exchanger type Separated;
Max pressure in the DHW circuit, atm 8;
Min pressure in the DHW circuit, atm 0.6;
Performance 916; DHW 30C, l / min 13.8;
Min consumption of natural gas, msup3; / h 0.95;
Max natural gas consumption, msup3; / h 1.72;
Min consumption of liquefied gas, kg / h 0.79;
Max consumption of liquefied gas, kg / h 1.43;
Nominal pressure of natural gas, mbar 25;
Chimney connecting diameter, mm No;
Gas pipeline connecting diameter, inch 1/2;
Separate chimney diameter, mm No;
Connecting diameter heating circuit, inch 3/4;
Connecting diameter DHW circuit, inch 1/2;
Electric power, W 150;
Current frequency, Hz 50;
Mains voltage, V 220 V;
Dimensions HxWxD, cm 69.5x44x26.5;
Weight, kg 28;
Warranty 2 years;
type of instalation Vertical;
Weather-dependent automation No;
Self-diagnosis No;
Underfloor heating mode No;
Remote control No;
Frost protection Yes;
Overheat protection thermostat No;
Low NOx level No;
Electronic control system Yes;
Mechanical control system No;
Pressure gauge Yes;
Condensate protection of the heat exchanger No;
Ionization flame control No;
Anti-blocking pump Yes;
Bypass loop No;
Functional LCD No;
Emergency coolant discharge No;
Electronic cascade control unit No;
Gas valve Multiblock No;
Can be installed in a residential area None;
Operation in a separate boiler room No;
Russified interface Yes;
Intuitive controls Yes;
Height-adjustable boiler legs No;
Water flow sensor No;
Height, cm 70;
Width, cm 44;
Depth cm 27;
Width 440;
Height 695;
Depth 265;
Country Korea;
Production Korea;
Boiler type Volatile;
Working hours Heating / hot water supply;
The combustion chamber Closed;
Burner Modulated;
Max power, kW 24;
Min power, kW 9;
Max pressure will heat the circuit, atm 3;
Min pressure will heat the circuit, atm 0.3;
Expansion tank Yes;
Circulation pump Yes;
Built-in storage boiler No;
Possibility of connecting a hot water boiler No;
Heat exchanger type Steel;
Max pressure in the DHW circuit, atm 8;
Min pressure in the DHW circuit, atm 0.3;
Performance 916; DHW 30C, l / min None;
Max natural gas consumption, msup3; / h 2.58;
Max consumption of liquefied gas, kg / h 2.15;
Nominal pressure of natural gas, mbar 10;
Chimney connecting diameter, mm 60x100;
Gas pipeline connecting diameter, inch 1/2;
Separate chimney diameter, mm 80/80;
Connecting diameter heating circuit, inch 3/4;
Connecting diameter DHW circuit, inch 1/2;
Electric power, W 150;
Current frequency, Hz 50;
Mains voltage, V 220 V;
Dimensions HxWxD, cm 69.5x44x26.5;
Weight, kg 28;
Warranty 2 years;
type of instalation Wall-mounted;
Weather-dependent automation No;
Self-diagnosis No;
Underfloor heating mode No;
Remote control No;
Frost protection Yes;
Overheat protection thermostat No;
Low NOx level No;
Electronic control system Yes;
Mechanical control system No;
Pressure gauge No;
Condensate protection of the heat exchanger No;
Ionization flame control No;
Anti-blocking pump Yes;
Bypass loop No;
Functional LCD Yes;
Emergency coolant discharge No;
Electronic cascade control unit No;
Gas valve Multiblock No;
Can be installed in a residential area No;
Operation in a separate boiler room No;
Russified interface No;
Intuitive controls Yes;
Height-adjustable boiler legs No;
Water flow sensor No;
Height, cm 70;
Width, cm 44;
Depth cm 27;
Width 440;
Height 695;
Depth 265;
Country Korea;
Production Korea;
Boiler type Volatile;
Working hours Heating / hot water supply;
The combustion chamber Closed;
Burner Modulated;
Max power, kW 24;
Min power, kW 9;
Max pressure will heat the circuit, atm 3;
Min pressure will heat the circuit, atm 0.6;
Expansion tank Yes;
Circulation pump Yes;
Built-in storage boiler No;
Possibility of connecting a hot water boiler No;
Heat exchanger type Steel;
Max pressure in the DHW circuit, atm 8;
Min pressure in the DHW circuit, atm 0.3;
Performance 916; DHW 30C, l / min None;
Max natural gas consumption, msup3; / h 2.58;
Max consumption of liquefied gas, kg / h 2.15;
Nominal pressure of natural gas, mbar 10;
Chimney connecting diameter, mm 60x100;
Gas pipeline connecting diameter, inch 1/2;
Separate chimney diameter, mm 80/80;
Connecting diameter heating circuit, inch 3/4;
Connecting diameter DHW circuit, inch 1/2;
Electric power, W 150;
Current frequency, Hz 50;
Mains voltage, V 220 V;
Dimensions HxWxD, cm 69.5x44x26.5;
Weight, kg 28;
Warranty 2 years;
type of instalation Wall-mounted;
Weather-dependent automation No;
Self-diagnosis No;
Underfloor heating mode No;
Remote control Yes;
Frost protection Yes;
Overheat protection thermostat No;
Low NOx level No;
Electronic control system Yes;
Mechanical control system No;
Pressure gauge Yes;
Condensate protection of the heat exchanger No;
Ionization flame control No;
Anti-blocking pump Yes;
Bypass loop No;
Functional LCD No;
Emergency coolant discharge No;
Electronic cascade control unit No;
Gas valve Multiblock No;
Can be installed in a residential area No;
Operation in a separate boiler room No;
Russified interface Yes;
Intuitive controls Yes;
Height-adjustable boiler legs No;
Water flow sensor No;
Height, cm 70;
Width, cm 44;
Depth cm 27;
Width 440;
Height 695;
Depth 265;
Country Korea;
Production Korea;
Boiler type Volatile;
Working hours Heating / hot water supply;
The combustion chamber Closed;
Burner Modulated;
Max power, kW 35;
Min power, kW 12;
Max pressure will heat the circuit, atm 3;
Min pressure will heat the circuit, atm 0.5;
Expansion tank Yes;
Circulation pump Yes;
Built-in storage boiler No;
Possibility of connecting a hot water boiler None;
Heat exchanger type Separated;
Max pressure in the DHW circuit, atm 8;
Min pressure in the DHW circuit, atm 0.3;
Performance 916; DHW 30C, l / min 20.1;
Min consumption of natural gas, msup3; / h 0.75;
Max natural gas consumption, msup3; / h 3.77;
Min consumption of liquefied gas, kg / h 0.63;
Max consumption of liquefied gas, kg / h 3.14;
Nominal pressure of natural gas, mbar 10;
Chimney connecting diameter, mm 80;
Gas pipeline connecting diameter, inch 3/4;
Separate chimney diameter, mm 80;
Connecting diameter heating circuit, inch 3/4;
Connecting diameter DHW circuit, inch 1/2;
Electric power, W 150;
Current frequency, Hz 50;
Mains voltage, V 230 V;
Dimensions HxWxD, cm 66.5x44x25.5;
Weight, kg 27;
Warranty 3 years;
type of instalation Vertical;
Weather-dependent automation No;
Self-diagnosis Yes;
Underfloor heating mode No;
Remote control No;
Frost protection Yes;
Overheat protection thermostat Yes;
Low NOx level No;
Electronic control system Yes;
Mechanical control system No;
Pressure gauge Yes;
Condensate protection of the heat exchanger No;
Ionization flame control Yes;
Anti-blocking pump Yes;
Bypass loop No;
Functional LCD Yes;
Emergency coolant discharge No;
Electronic cascade control unit No;
Gas valve Multiblock No;
Can be installed in a residential area None;
Operation in a separate boiler room No;
Russified interface Yes;
Intuitive controls Yes;
Height-adjustable boiler legs No;
Water flow sensor No;
Height, cm 67;
Width, cm 44;
Depth cm 26;
Width 440;
Height 665;
Depth 255;