Why flowing refrigerator: causes and remedy failures

Refrigerator all year, but the device did not pay attention until there is a failure. Half of the people are faced with the Dribble, when moisture collects on the bottom of the camera. If the problem persists, then the water under the refrigerator will be collected in puddles on the floor, and the leakage rate increase. The causes of leakage can become defective mechanical or electronic component device and negligence in the operation. To completely solve the problem, it is necessary to deal with the source of the problem.

Before seeking technical defects of the device, it is necessary to exclude standard causes. Check the outlet into which the refrigeration unit, and plug. If the contact surfaces are covered with an oxide film and traces of soot - hence, from the device water flowing due to power failure. Poor contact in the plug connection may cause overheating, melting of the insulator and short circuiting. Hence, it is necessary to replace the wiring connection parts.

When, after his absence, the owners discovered that there was water in the fridge, the cause could be a power outage. De-energized device is thawed and sprung a leak.

If inclusion in the network does not solve the problem, you need to find a probable fault.

Scored drain hole

When water accumulates at the bottom of the refrigerator, it follows from under the wings, it formed a puddle on the floor - these are signs of clogging the drainage system. A problem arises with devices thawing drip.

When negligent use, untimely cleaning chamber surfaces within residues accumulate products crumb formed mold. The particles clog drainage lumen causing a blockage, causing condensate discharge impossible. Accumulate moisture leaking under the boxes below, it falls to the floor. Supercooled condensate surplus on the walls turn into ice, exacerbating the clogging.

The reason for abundant formation of melt water is removed the cleaning of the drainage opening located in the lower portion of the rear wall of the refrigerator.

The solution is to own:

  1. De-energized refrigerator, take out the products. Then thawed when the doors are open till six o'clock.
  2. Q-tip clean pollution from the lumen of the drain hole.
  3. Drawn into a syringe or syringe volume water temperature 60-80 ° C and under pressure is supplied to the drain.
  4. Washing with warm water and continue until the liquid flows from the drain hose into a tray located on the back of the refrigerator.

If the water flows out of the freezer through the seal and is formed on the door snow crust - drain hole clogging occurs in this compartment. the freezer drain can be cleaned in the same manner as in the refrigerator.

The procedure can complicate the arrangement of draining deep beneath the veneer. Here without a specialist can not do, because to do cleaning without having the skills and tools recklessly.

To the problem appeared again follow the cleanliness of internal surfaces of the device's camera. Remove food residues from the shelves or walls at least wash contamination device with detergent. As preventive apparatus can be periodically defrosted and clean drainage holes cotton swab.

The crack in the liquid container

It happens that the device works without disturbing the temperature. Inside the chambers there is no condensate, and the fluid flows out of the refrigerator is detected, or only the rear. There is likely to damage the tray.

a reservoir for water damage

To check the water tank, it is necessary to move the refrigerator, remove the container and check for cracks.

Water receiver is made of plastic. From the compressor is running, the container is subjected to overheating. With time Elevated temperatures cause deformation and cracks. Breach of the vessel integrity - that is why at the rear of the cooler water flowing on the floor.

The obvious solution to breakage - the replacement of the container to the next. Capacity can be temporarily replaced by a suitable size jar or plastic box.

Problem with drain pipe

Symptoms of the problem is similar to the tank breakage - the liquid flows to the floor, and the refrigerator and freezer remain dry. If the drain container in order, check the output connection of the drain hose.

To eliminate leaks need to move the unit who quit and connect the hose to the drain outlet.

Problems with integrity

Water flows inside the refrigerator without stopping due to the large amounts of condensate. Moisture is formed due to depressurization of the chamber and the temperature rise. This occurs when the wear of the sealing profile and is not completely closed the door.

Wear rubber bands often inevitable failure. Cooling reduces elasticity and moisture, oxidation air eventually leads to cracking and looseness sealant.

Eliminate the fault help replacing the sealing rubber or adjust the refrigerator door hinges.

Faulty thermostat

Damaged thermostat can not cope with the measurement of temperature. Compressor ceases to run or work in violation of the cycle. A refrigerator chamber is heated, causing the melting of ice on the back wall.

Repair damage reduced to replacing burnt-defective sensor. It will have to contact the service center or to the master.

External factors

The water near the refrigerator may not be formed due to a fault, there may be other reasons:

  • device costs close to the wall, which causes overheating of the evaporator;
  • the machine is near the radiator or the cooker;
  • indoor high temperature, so the compressor can not cope;
  • set the operation mode to a minimum;
  • power cord is damaged or the plug;
  • interruptions of electricity supply and low voltage network;
  • leakage associated with a spill of water from other appliances - sink, washing machine.

Elimination of possible factors affecting the operation of the equipment to help with the leak.

Flowing refrigerator No Frost

Aggregates with the technology of automatic defrost heater are provided for draining the condensate and reduce the amount of ice. When this part breaks, increased condensation. Partially water freezes on the surface, while the rest will flow freely through drain pipes in the collection. The reservoir and overflow water is discharged under the refrigerator.

Disassemble and install electronic components operating without training hard. No Frost phones can be repaired at the service center to replace the defroster.

Do not leave without attention to the leak. the formation of water - a sign of failure or improper operation. If the fluid appears in the refrigerator compartment or on the floor, you need to defrost the unit, clean it from dirt, washed and inspected for damage. When their own reason can not be found, it is necessary to turn to professionals.