🌡 thermostat for floor heating: types, popular model and installation procedure

If you want to make in the house it was always warm and comfortable, the thermostat for underfloor heating It will help to ensure optimum heat flooring. Such devices are part of the thermal circuit, allow to optimize power consumption and extend the life of the system. We offer more detail to understand the features of these devices, their types and the order of installation.

The floor can be heated in a strictly predetermined range
The floor can be heated in a strictly predetermined range

Read article

  • 1 Appointment thermostat for floor heating
  • 2 The device and principle of operation
  • 3 Variety of temperature sensors for floor heating
    • 3.1 Mechanical and electronic
    • 3.2 Programmable and remote
  • 4 Leading manufacturers of thermostats for underfloor heating
  • 5 Popular models
    • 5.1 Teplolux TR 515: Rating 5/5
    • 5.2 DEVI reg touch: Rating 4.5 / 5
    • 5.3 Jiahong Warmlife: Rating 4.5 / 5
  • 6 How to choose a thermostat for floor heating: the basic criteria and general recommendations
    • 6.1 By allowable power and a method for mounting
    • 6.2 In appearance and functionality
  • 7 Mounting the thermostat
  • 8 Preparatory work
    • 8.1 Step by step instructions on connecting
    • 8.2 operability test
  • 9 Rules of operation of the thermostat for floor heating

Appointment thermostat for floor heating

The main purpose of the unit is temperature control. He is part of the technological systems of various kinds. Can connect to aqueous the warm and electrical floor. Use it to create comfortable living conditions, as well as to prevent overheating of the floor heating by controlling the degree of coverage of heating.

The thermostat will set the temperature of the floor covering
The thermostat will set the temperature of the floor covering

The device and principle of operation

Design thermostats for floor heating may vary. It all depends on what type of coolant used. Manufacturers offer thermostats for water and electric underfloor heating. The first type is a termosmesitelny valveAllowing to adjust the ratio of hot and chilled coolant (Air or water) entering the heating zone. Electrical thermostats allow you to change the current in the heating circuit. Due to this, changing the amount of heat generated.

Suitable for floor water valve termosmesitelny
Suitable for floor water valve termosmesitelny

The device is connected to the heating circuit, and the sensor to the power supply. In progress thermoregulator It performs the following:

  • reading from a temperature sensor information about the degree of heating of the floor covering;
  • compares the obtained data with the values ​​set by the user;
  • switch off the heating if the maximum temperature is exceeded, connects or if the value does not reach the required minimum.

Attention! Due to the fact that the cycle is repeated constantly, it becomes possible to provide uniform heating of the floor covering.

Information from the sensor determines the mode of operation of the thermostat
Information from the sensor determines the mode of operation of the thermostat

Variety of temperature sensors for floor heating

Before you give preference to a particular model, it is necessary to deal with the existing varieties. On this depends the operating principle, the cost and operation of the thermostat conditions for floor heating.

The design of the temperature sensor determines the mode of operation
The design of the temperature sensor determines the mode of operation

Mechanical and electronic

Mechanical devices do not have electronic components. Wires for connection underfloor heatingPass directly through the thermostat, which can deliver a certain discomfort when performing assembly work.

As the temperature sensor in a mechanical device acts a bimetallic plate, make and break contacts. Their constituent limit switch is used to enable and disable the heating temperature without adjustment possibilities. Changing the settings carried out by means wheel.

Mechanical temperature sensors are relatively simple execution
Mechanical temperature sensors are relatively simple execution

Electronic devices may appear to be similar to the mechanical, but run on batteries. The design assumes that:

  • supervisory ICs;
  • temperature sensorWhich may be external or integrated;
  • an electronic key that is used to supply or power outage;
  • housing.

To control the device can be used by adjusting the wheel, buttons, touch screen, or a combination thereof. Some models allow you to adjust the temperature in several areas. This is possible thanks to an independent connection to the controlling chip multi-zone underfloor heatingIsolated from each other.

Electronic devices provide greater control accuracy
Electronic devices provide greater control accuracy

Programmable and remote

programmable thermostats have expanded functionality. They help to set the temperature of the floor covering, depending on the time of day. This makes it possible to optimize energy costs, which is especially important for homes in which one does not live permanently. Cost programmable devices depends on many factors, including the quality and quantity characteristics of the display of monitored parameters.

It sets not only the temperature but also the time
It sets not only the temperature but also the time

ROV consist of two blocks: a base and a mobile. The main unit is connected to the temperature sensors. It can be placed anywhere, which greatly simplifies the installation work. Cell associated with the base and may be placed in the public domain. For convenience, many manufacturers are using smartphone apps, you can use to adjust the equipment settings.

Change the degree of heating the floor covering can be using the remote
Change the degree of heating the floor covering can be using the remote

Leading manufacturers of thermostats for underfloor heating

High-quality products produced by many manufacturers. We advise you to pay attention to the temperature regulators issued under the trademarks:

  • Legrand. French manufacturer offering high quality products, characterized by high quality workmanship. They are easy to use, easy to manage;
  • Valena. Products of the manufacturer has an attractive design, interesting design and long service life. You can select the type of control: an electronic or mechanical. quality plastic is used to manufacture products. Thermostats have high operational characteristics;
  • Devi. Devices of this manufacturer are very precise. Possible regulation in a narrow range. The manufacturer offers a range of products, which will choose the best option for a particular system design and functionality;
  • "Teplolux". Availability and quality of the thermostats enables the manufacturer to occupy a leading position among peers. Large range allows you to choose the device with the appropriate functionality. The company offers mechanical and electronic models, including programmable;
  • Electrolux. Manufacturer of Sweden manufactures its products in China. The simple design concept makes a convenient operation of thermostats;
  • Energy. The company, specializing in the production heating equipmentIt offers quite a large range of thermostats;
  • Eberle. The German manufacturer offers a different type of device.
Devi offers mechanical and electronic model
Devi offers mechanical and electronic model
Electrolux offers stylish models
Electrolux offers stylish models

Popular models

To make the final choice, it is necessary to get acquainted with popular models. Such devices are of high quality, but because demand among users. Perhaps our rankings to help you make the right choice.

The thermostat must fit harmoniously into the interior
The thermostat must fit harmoniously into the interior

Teplolux TR 515: Rating 5/5

Non-programmable digital device designed to control electric heated floors. To stabilize the operation of the system. 0,50ºS control accuracy is in the range from 50 ° C to 350 ° C. protection class IP 20. Stylish appearance makes the model relevant to any interior. Size 86 × 86 × 35 mm with a weight of 90 g.

Feedback on thermostat for floor heating "Teplolux" TR 515:

Thermostat for floor heating: design features of different types of mounting methods
More on Otzovik: https://otzovik.com/review_5483568.html

thermostat for floor heating "Teplolux» TP 515

DEVI reg touch: Rating 4.5 / 5

Electronic programmable model, powered by a 220 V network Designed for a resistive load of 16 A. It can be operated at a temperature of from + 50C to + 300 ° C. It provides protection against freezing. At night, the temperature decrease may be programmed to 0 ° C. It complies with IP21. It has dimensions of 85 × 85 × 44 mm.

Reviews of the controller for the electric floor heating DEVI reg touch:

More on Otzovik: https://otzovik.com/review_4395492.html
More on Otzovik: https://otzovik.com/review_4395492.html

Controller for electric floor heating DEVI reg touch

Jiahong Warmlife: Rating 4.5 / 5

The model of the Chinese manufacturer is characterized by high quality workmanship. Calculated on a maximum current of 16 A at a power of 3.6 kW. The size of 9 × 9 × 4 cm with a weight of 0.2 kg. There is a built-in temperature sensor and the wire.

Review of the programmable thermostat for floor heating Jiahong Warmlife:

Thermostat for floor heating: design features of different types of mounting methods
More on Otzovik: https://otzovik.com/review_7278563.html

programmable thermostat for floor heating Jiahong Warmlife

How to choose a thermostat for floor heating: the basic criteria and general recommendations

That the house was really comfortable, the choice of the thermostat for the floor, it is necessary to take into account a number of factors. Incorrectly selected model may cause undesired operation of the system and deliver a serious inconvenience in operation. We offer to meet the basic criteria that you should be sure to remember when choosing the right model for your home.

The choice depends on many factors
The choice depends on many factors

By allowable power and a method for mounting

Each model is designed for a certain capacity, which contains the maximum value of the device. When you select should be considered the same parameters required to underfloor heating. Power thermostat must be higher than 15 - 20%. In this case, the device will last much longer.

Attention! If the room has a large area, it will take several thermostats.

Power - one of the most important criteria
Power - one of the most important criteria

Method of installation is also an important criterion in the selection. Available boards and wall mounted device. The first option is relevant for large rooms. The second involves the placement of the thermostat near sockets or a switch board. If installation will be carried out in an apartment or a house, the choice is usually made in favor of the wall mounting.

Attention! If the installation will be carried out in a wooden house, it is necessary to give preference to the invoice model.

Home actual wall installation
Home actual wall installation

In appearance and functionality

device design and its color may differ materially. When you are choosing to be guided by stylistic design of the roomIn which the system will be installed. Be sure to consider how it will be convenient to use a specific device.

For an apartment you can always choose a stylish model
For an apartment you can always choose a stylish model

The functional unit deserves special attention. The more features, the more expensive the cost model and will more precisely control the temperature. This will optimize the work of underfloor heating and reduce the cost of its operation. Some devices allow you to control a number of additional parameters. However, their cost is always much higher than that of similar devices with less functionality.

Functionality depends on the model
Functionality depends on the model

Mounting the thermostat

If you decide to install your own hands, you should carefully understand the order of performance. Violation of technology can cause improper operation of thermostat. We offer to understand the intricacies of the process.

Preparatory work

Prior to installation you should carefully read these instructions. It is painted in detail the procedure for the installation work, the violation of which is unacceptable. If you plan to install the built-in models, kindly, to determine the place to prepare a recess of the correct size. The thermostat should be located on a height of 0.6 - 1 m from the floor near sockets.

Attention! Before starting work, always disconnect the power supply, pre-defined zeros and phase.

Driving thermostat connection
Driving thermostat connection

Step by step instructions on connecting

Connect the thermostat for floor heating is performed in the following sequence:

IllustrationDescription of the action
Thermostat for floor heating: design features of different types of mounting methodsPre-cut electricity, cut off the excess wire, and we clean the ends.
Thermostat for floor heating: design features of different types of mounting methodsGuided scheme specified immediately on the device, connect power and temperature sensor.
Thermostat for floor heating: design features of different types of mounting methodsVia terminal block connect directly grounding. The temperature sensor is twisted and put in box.
Thermostat for floor heating: design features of different types of mounting methodsInstall the thermostat into the prepared cavity. Fasten with screws. Set the top of the trim.

We offer also see the following video to understand in more detail the procedure for installation work:

operability test

After installing the thermostat, check its performance. For this:

  • connect electricity;
  • We turn the thermostat and watch the display information;
  • expose the desired operating mode.
Glowing red light signals the beginning of the heating
Glowing red light signals the beginning of the heating

Rules of operation of the thermostat for floor heating

To mount the system lasts as long as possible, you should carefully examine the recommendations of the manufacturer. If you specify a certain temperature range in which can operate the unit, do not break it. Do not exceed the recommended value of the power and amperage. Timely remove from the surface of the thermostat accumulated dust. Do not use to remove stubborn dirt solvents.

Tip! If the device started to show incorrect values, repair devices Rely on professionals.

Share in the comments what you purchased thermostat for floor heating in your home, and how to perform the installation.