If the home is increased humidity, Become wet walls, fix the situation will shut-off waterproofing. There are different ways, each of which deserves special attention. Offer to meet with the available solutions.
Read article
- 1 Cut-off waterproofing: it and its main purpose
- 2 The operating principle of the shutoff waterproofing depending on the type
- 2.1 Horizontal waterproofing shut-off: distinctive features
- 2.2 Impregnating waterproofing shut-off
- 3 The technology of works on waterproofing shutoff
- 3.1 Installation of the shut-off roll waterproofing
- 3.2 Apparatus shutoff waterproofing method inektsionirovaniya: main stages
- 4 The choice of materials for waterproofing shutoff
- 4.1 Brand "TechnoNikol"
- 4.2 Cut-off waterproofing "Renovir": area of use
Cut-off waterproofing: it and its main purpose
No matter what kind of soil on the site, in it necessarily contains a certain amount of moisture. When precipitation, melting snow, the rise of ground water level of humidity increases, which has a negative impact on the foundation and the walls of the house.
As a result, the service life of the structure is significantly reduced. Deciding provided during construction waterproofing shutoff "TechnoNikol" width of 400 mm or other size, can prevent a negative impact on the supporting structures and create a more comfortable living conditions inside houses. Quality gidrobarer become a reliable barrier to the moisture penetrating from the ground into the walls or base, as well as other components.
The operating principle of the shutoff waterproofing depending on the type
Offers manufacturers waterproofing materials can have different operating principle. To understand how it works, "TechnoNikol 400" shut-off for waterproofing foundation, It is necessary to know its characteristics and method of installation. We offer to understand the basic types and their distinctive features.
Horizontal waterproofing shut-off: distinctive features
Apparatus cutoff roll waterproofing is performed using materials having polymer-bitumen and bitumen-based. Manufacturers offer rolls of varying widths, which allows you to choose the best option depending on the protected area. The most widely used material of width 400 mm and 600 mm.
Attention! Due to the high performance characteristics of waterproofing shut-off "TechnoNikol 600" and "400 TechnoNikol" able to prevent penetration of moisture to the interior walls with a thickness of 1 mm strips.
Horizontal waterproofing mounted shut-off in the process of building a house:
Impregnating waterproofing shut-off
Cut-off cap waterproofing can be performed using penetrating material. They are injected into a pre-drilled hole, forming a reliable and sturdy gidrobarer for the entire surface to be protected.
Comment
Mikhail Starostin
Team leader repair and construction company "Home Premium"
«Composition for Gidrobarer device selected according to the material used to manufacture the protected surface. "
For brick, concrete or bedrock required siloxane silicone mixture to form within the cavities allowing water resistant film. If the base is present in the composition of lime, lime require an alkaline solution.
Attention! Penetrant compounds can perform processing wall being built not only houses, but also long been constructed.
The technology of works on waterproofing shutoff
The order of assembly work depends on the type of waterproofing material. If you decide to use a waterproofing cut-off "TechnoNikol 400", be sure to read the instructions for use, are pasted on each roll. The order of the injection device will be slightly different. We propose to consider each method in more detail.
Installation of the shut-off roll waterproofing
To find out how to apply a waterproofing cut-off "TechnoNikol 400" to handle the cap or walls of the building, should be familiar with the manufacturer's recommendations. Considering that at a temperature below + 15 ° C, the material becomes fragile, must perform work during the warm season. To ensure proper connection of the main waterproofing layer formed, the latter should be done at 5-10 cm wider than the wall. The projecting portion is connected to the waterproofing foundation and sex.
Attention! Using a cut-off wall waterproofing true for all buildings, including those built on the Velox technology.
If you plan to perform works at low temperature instead of polymer-bitumen and bituminous materials should be chosen based on PVC rolls, synthetic rubber or polyolefin. The choice in favor of PVC is in the case for protection foundation material used on the same basis. In this situation, the use of bitumen compositions inadmissible, as under their impact PVC cracked.
The work is performed in the following sequence:
- is applied onto the surface layer cement solution or mastic thickness of 1 cm;
- "TechnoNikol 600" rolled shut-off waterproofing. In accordance with the instructions for assembling, the width formed by the layer should be larger than the width 5-10 cm foundation;
- a layer of cement of the same thickness.
Attention! For joining strips of web material is used rubber cement, bitumen mastic, and a number of other compositions, depending on the type of protection.
As shut-off is performed using a basement waterproofing material TechnoNikol 4 × 20m, demonstrated in the following form:
Apparatus shutoff waterproofing method inektsionirovaniya: main stages
Apparatus shutoff inektsionirovaniya waterproofing method is performed in the following sequence:
- a protected base in a staggered diameter holes drilled 25-32 mm. To form the cavity should be in increments of 25-30 cm at an angle of not less than 35 °. The optimum angle is 45 °. The depth of the holes formed must be not less than ⅔ plinth or wall thickness;
- formed cavity wash water;
- fill holes trained staff.
The last stage of discharge can be performed either pressureless manner. The first option involves using a special pump, allowing to provide sufficient pressure. The process is relevant at high content (over 50%) of moisture in the ground. A large percentage of water content of the composition does not allow rapidly absorbed.
At low humidity levels can use pressureless method. This method involves filling holes through the usual funnel during the day. As absorption into the wall composition mixture pour. After impregnating the base holes sealed with mortar.
We offer watch a video, which clearly shows how the work is done:
The choice of materials for waterproofing shutoff
If you decide to buy a cut-off waterproofing, you should choose products trusted manufacturers, such as "TechnoNikol" or "Renovir". We offer to experience the product data producers.
Brand "TechnoNikol"
Manufacturers offer high-quality material on the bitumen-polymer-based. Price shutoff waterproofing "TechnoNikol" depends on its size. In the production process polyester substrate is impregnated with bitumen-polymer binder, which is based on bitumen, polymer modifier and special additives. To ensure sufficient performance, the web is coated on both sides with protective layers, such as nonwoven polypropylene (spunbond).
Review of the shutoff waterproofing "TechnoNikol 400":
Before you give preference to a particular mind, it is necessary to know at what price in rubles .:
Mark | Characteristics |
"TechnoNikol 400" | Area - 20 square meters. Roll length - 20 m Lifetime -. at least half a century. Weight - 8 kg. |
"TechnoNikol 600" | Weight - 12 kg. For brick, wood, concrete and other bases. |
"TechnoNikol 1 × 10" | bands width - 1 m. Roll length - 10m. Weight - 15 kg. |
Cut-off waterproofing "Renovir": area of use
Composition "Renovir" is used for the horizontal cut-off device protivokapillyarnoy waterproofing. It provides high hydrophobizing effect. Suitable for thick walls. Saves water vapor permeability of the construction. Capillary can be used for protection of stone, brick and reinforced base.
Share in the comments, how do you protect the base and walls from moisture.