Fortuna boiler: prices from 22 800 ₽ buy inexpensively in the online store

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Open;

Burner Modulated;

Max power, kW 16;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 13;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 2.18;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 2.96;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 133;

Gas pipeline connecting diameter, inch 1/2;

Separate chimney diameter, mm 133;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 90;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 34;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Open;

Burner Modulated;

Max power, kW 20;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.3;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 2.41;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 3.28;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 133;

Gas pipeline connecting diameter, inch 1/2;

Separate chimney diameter, mm 133;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 90;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 34;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production Italy;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Open;

Burner Modulated;

Max power, kW 24,0;

Min power, kW 7,2;

Max pressure will heat the circuit, atm 3,0;

Min pressure will heat the circuit, atm 0,3;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8,0;

Min pressure in the DHW circuit, atm 0,1;

Performance 916; DHW 30C, l / min 11,3;

Max natural gas consumption, msup3; / h 1,81;

Max consumption of liquefied gas, kg / h 1,33;

Nominal pressure of natural gas, mbar 1025;

Chimney connecting diameter, mm 133;

Gas pipeline connecting diameter, inch 1/2;

Separate chimney diameter, mm None;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 90;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 34;

Warranty 2 years;

type of instalation Wall-mounted;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area Yes;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Open;

Burner Modulated;

Max power, kW 11;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.3;

Max natural gas consumption, msup3; / h 2.18;

Min consumption of natural gas, msup3; / h None;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 2.96;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 133;

Gas pipeline connecting diameter, inch 3/4;

Separate chimney diameter, mm 133;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 90;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 34;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Open;

Burner Modulated;

Max power, kW 13;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.3;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 2.41;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 3.28;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 133;

Gas pipeline connecting diameter, inch 1/2;

Separate chimney diameter, mm 133;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 90;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 34;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Closed;

Burner Modulated;

Max power, kW 16;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.4;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 1.35;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 1;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 80;

Gas pipeline connecting diameter, inch 3/4;

Separate chimney diameter, mm 80;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 100;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 35;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room Yes;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Closed;

Burner Modulated;

Max power, kW 13;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.4;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 1.18;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 0.88;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 80;

Gas pipeline connecting diameter, inch 3/4;

Separate chimney diameter, mm 80;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 100;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 35;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room Yes;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Closed;

Burner Modulated;

Max power, kW 10;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.4;

Max natural gas consumption, msup3; / h 1.1;

Min consumption of natural gas, msup3; / h None;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 0.75;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 80;

Gas pipeline connecting diameter, inch 3/4;

Separate chimney diameter, mm 80;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 100;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 35;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room Yes;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Closed;

Burner Modulated;

Max power, kW 20;

Min power, kW 7.2;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 11.4;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 1.58;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 1.17;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 80;

Gas pipeline connecting diameter, inch 3/4;

Separate chimney diameter, mm 80;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 100;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 35;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD No;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room Yes;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Closed;

Burner Injection;

Max power, kW 32;

Min power, kW 10;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm None;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Separated;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm None;

Performance 916; DHW 30C, l / min 22;

Min consumption of natural gas, msup3; / h 0.88;

Max natural gas consumption, msup3; / h 3.4;

Min consumption of liquefied gas, kg / h 0.65;

Max consumption of liquefied gas, kg / h 2.7;

Nominal pressure of natural gas, mbar 25;

Chimney connecting diameter, mm 80;

Gas pipeline connecting diameter, inch 1/2;

Separate chimney diameter, mm 80;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 110;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x44x23.5;

Weight, kg 38;

Warranty 1 year;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control No;

Anti-blocking pump Yes;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge No;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls No;

Height-adjustable boiler legs No;

Water flow sensor No;

Height, cm 74;

Width, cm 44;

Depth cm 24;

Width 440;

Height 742;

Depth 235;

Country Italy;

Production China;

Boiler type Volatile;

Working hours Heating / hot water supply;

The combustion chamber Closed;

Burner Modulated;

Max power, kW 40;

Min power, kW 11.8;

Max pressure will heat the circuit, atm 3;

Min pressure will heat the circuit, atm 0.8;

Expansion tank Yes;

Circulation pump Yes;

Built-in storage boiler No;

Possibility of connecting a hot water boiler None;

Heat exchanger type Lamellar;

Max pressure in the DHW circuit, atm 8;

Min pressure in the DHW circuit, atm 0.1;

Performance 916; DHW 30C, l / min 18.7;

Min consumption of natural gas, msup3; / h None;

Max natural gas consumption, msup3; / h 2.18;

Min consumption of liquefied gas, kg / h None;

Max consumption of liquefied gas, kg / h 2.96;

Nominal pressure of natural gas, mbar 20;

Chimney connecting diameter, mm 80;

Gas pipeline connecting diameter, inch 1/2;

Separate chimney diameter, mm 80;

Connecting diameter heating circuit, inch 3/4;

Connecting diameter DHW circuit, inch 1/2;

Electric power, W 125;

Current frequency, Hz 50;

Mains voltage, V 220 V;

Dimensions HxWxD, cm 74.2x50x34.4;

Weight, kg 42;

Warranty 2 years;

type of instalation Vertical;

Weather-dependent automation No;

Self-diagnosis Yes;

Underfloor heating mode No;

Remote control No;

Frost protection Yes;

Overheat protection thermostat Yes;

Low NOx level No;

Electronic control system Yes;

Mechanical control system No;

Pressure gauge Yes;

Condensate protection of the heat exchanger No;

Ionization flame control Yes;

Anti-blocking pump No;

Bypass loop No;

Functional LCD Yes;

Emergency coolant discharge Yes;

Electronic cascade control unit No;

Gas valve Multiblock No;

Can be installed in a residential area None;

Operation in a separate boiler room No;

Russified interface No;

Intuitive controls Yes;

Height-adjustable boiler legs No;

Water flow sensor Yes;

Height, cm 74;

Width, cm 50;

Depth cm 34;

Width 500;

Height 742;

Depth 344;