Ecover light: specifications (35, 45, 50, 80, 90, 100 mm), density, composition

click fraud protection

Modern building materials market can please a new type basalt insulation - Ecover. It is absolutely safe for humans, because the manufactured exclusively from rocks. Due to its unique properties is capable of firmly withstand various types of loads and environmental influences.

Specifications "Ecover Light"
emblem Ecover

Brand itself offers a wide variety of thermal insulators for all occasions.

insulation Application

This material is used for all kinds of designs to provide robust and reliable layer of acoustic and thermal insulation. Basically, Ecover is designed for mounting on:

  • frame walls;
  • attics;
  • attics;
  • internal partitions;
  • floors;
  • facades.

Thermal insulation has high rates of thermal protection and physical and mechanical properties, which ensures an optimal indoor climate and durability.

Specifications "Ecover Light"
Thermal insulation of the roof with the aid of light Ecover

Data Manufacturer

Thermal insulation Ecover produced on modern Russian plant in the Sverdlovsk region. The choice of location was based on the proximity to the deposits of gabbro-basalt rocks. Due to the advanced technical equipment is achieved by the production of quality products capable of tackling the issues of improving energy efficiency and environmental performance of buildings.

The structure of a heater includes: set up on the basis of rock mineral wool and binder synthetic origin. At the same time, it meets all applicable standards GOST 9573-2012.

material Features

Properties Ecover Light suggest the practicality and necessity of this material:

  • heat preservation room, due to the fact that the material has a high coefficient of thermal conductivity (0.035 W per square meter);
  • due to absorption of the fiber structure is provided by extraneous noise;
  • ecology - in the manufacture of only natural materials are used;
  • Flameproof and combustibility - the temperature at which a material begins to melt should exceed 1000 degrees Celsius;
  • water resistance - can not be exposed to moisture;
  • vapor permeability - Ecover well lets air and steam, without creating a greenhouse effect in the room;
  • inertness to biological and chemical factors;
  • the ability to withstand high loads without deforming structure.
Specifications "Ecover Light"
What is Ecover light

Ecover Light has the following characteristics:

  • Dimensions: 100 cm - 60 cm and length - width.
  • Density - 28 - 60 kg / cu. meter.
  • Thickness - 50 - 200 mm.
  • Vlagopogloschaemost does not exceed the target of 1.5 percent of the total obe6ma.
  • The degree of compressibility - 8 - 15 percent.
  • The group of non-combustible materials.
  • The melting point of 1000 degrees.

types of products

Depending on the purpose of the insulation is available in several popular types, which differ among themselves, the parameters and scope.

Specifications "Ecover Light"
Wall insulation using basalt insulation
  • Wagon. This line is used for domestic work in private homes. This includes:
  • Light Ecover - has 3 types of density: 30 kg, 35 kg and 45 kg per square meter. They have a low moisture absorption level (1%) and the thermal conductivity of a standard type - 0,035-0,042 W mK. Compression ratio - 20%;
  • Ecover Universal Light - is applied to the surfaces where the temperature exposure is not more than 400 degrees. Compression ratio - 25%. Density - 28 kg per cubic meter.. Package 12 has plates, the total of which is 0.36 m. Cubic .;
  • Acoustics - designed to absorb noise, there is no shrinkage. Material Density - 35 kg per cubic meter.. Designed for mounting on frame partitions, interior walls, ceilings between floors, on the ceiling of the room, and between the lags;
  • Standard 50 - has two kinds of density 50 kg and 60 kg per cubic meter.. The percentage of compression is less than 6%. Characterized elevated strength values. Plates are packed in 12 pieces. Volume - 0.36 cubic meters..

Ecover parameters Standard

Value measurement
The nominal value of the density 45 kg per m. Cube
Thermal conductivity 0,035-0,036 W mK
The quantity of organic substances 3% by weight
moisture absorption No more than 1 kg per sq.m.

Presented types are mounted mainly on the loggia, lagged ceilings.

  • Series for facades. It consists of plates with higher density and better thermal insulation properties. The line includes:
  • Ekofasad - mounted on a wall, a thin layer of plaster. Designed for up to 40kPa. The degree of thermal conductivity - 0,035-0,041 Bk on mK;
  • decor - have a thickness of from 2 to 20 cm, tear strength indicator exceeds 80 kPa, the thermal conductivity - 0,039-0,043 W mK. Insulation for facade slabs to 6 packaged size 100h60h5 cm. Volume - 3.6 square meters .;
  • Vent facade 80, 90 - are used for exterior finishes and for finishing plaster reinforced with a grid on the surface. Density varies from 70 to 120 kg per m. Cu. The degree of moisture absorption - 0.75 percent. Packaging - 12 plate sizes 100h60h5 cm and a volume of 0.36 cubic meters..

Indicators of the main characteristics of

Value measurement index Number
Conduction of heat at 10/25 degrees W mK does not exceed 0,035 - 0,037
Tensile strength kPa at least 40
The quantity of organic components % not more than 4 by weight
  • For the roof. In this model presents several plates with a high degree of rigidity. Scope - operated roof. The degree of density - 135 - 150 kg per cubic meter.. Not recommended to use for the creation of attics and basements premises. The thickness of the material - 5 - 20 cm. Moisture absorption is not more than 0.75%. The quantity of organic substances in the composition no more than 4.5%. Ecover roofing sheets packed to 8, each having dimensions 100h60h5 cm. Volume - 0.24 cubic meters.

Data Sheet

Value What is measured Type of
135 150
Index of nominal density kg per cubic meter. 135 150
The degree of heat conductivity at 10/25 degrees W mK 0,038 – 0,039 0,038 – 0,039
Compression kPa at least 45 at least 50
Tensile direct impact load H no less than 600 at least 650
The boundary strength at stretching kPa about 10 about 12
  • Floor. It used herein Ecover Step a density of 135 kg per cubic meter. and STEP + - 150 kg per cubic meter.. Scope - mount floors, basement floors and basements. In addition, the insulation can be installed floor heating, concrete or cement-sand screed. Load capacity - 30-35 kPa.
Specifications "Ecover Light"
Insulation of floors Ecover Light

Technical indicators material

Value measurement amount
Thermal conductivity 10 - 25 degrees W mK 0,035 – 0,037
Compression ratio kPa at least 35
moisture absorption kg per m sq. not more than 0.75%
The presence of organic matter % no more than 4

material benefits

The broad scope of applicability of Ecover suggests the presence of positive characteristics:

  • the safety of technical indicators to temperature changes;
  • resistance to fungi and molds;
  • protection from exposure to ultraviolet rays;
  • ease of mounting;
  • long service life (over 50 years);
  • reasonable cost;
  • absence of extraneous odors;
  • a wide range of sizes.
Specifications "Ecover Light"
Packing light Ecover

Ecover Light - the best choice and practical solution for every home.